Snake-oil specs spell trouble for motor sizing
A well-behaved motion system depends on motor parameters derived from lab tests. When critical ratings are suspect, run the tests and measure the results yourself.
Also, look for current limits specified at the point where Kt rolls off because the motor saturates at that level, or at the knee of the B-H curve for the magnets used in the field assembly. Although the newer rare-earth magnets have a fairly straight load line in the second quadrant of the B-H curve as shown in the B-H curve operating points, many motors still use ceramic and AlNiCo magnets that partially demagnetize when exceeding the knee of the curve. Currents exceeding the peak rating generate high ampere-turns in the motor's armature and can drive the load point over the knee, permanently demagnetizing the motor's field assembly.
Even for rare-earth magnet motors, the load point may shift significantly on the BH curve. Most often, this point rebounds up the curve with lower applied current. Some manufacturers specify Kt at the lower currents, producing a higher sensitivity because the flux density is higher. A more appropriate value is the flux point at peak current, Ip. Regardless of the current level up to rated peak, the motor reaches calculated minimum torque.
High current levels combined with a sufficient number of turns in the winding may saturate the armature. This reduces Kt and makes the motor behave nonlinearly, much like the roll-off shown on the B-H curve. For example, consider a Kt = 10 oz-in./A at an input current of 5 A. At 50 A, the Kt might equal only 7 oz-in./A because the motor electromagnetically saturates. On the other hand, some published data sheets are accurate but show underrated motor performance. This is particularly true in the specialty motor business where ratings are often established from customer specifications rather than considering the full capabilities of a particular motor. Many of these motors might produce from 25 to 300% of rated torque. Although users may see this as an additional advantage, it makes a case for comparing the motor constant, Km, and to avoid reviewing only one parameter.
TOLERATE THE FIT
Most engineers design systems and components using worst-case tolerancing. Unfortunately, the method can oversize the system or understate the ultimate speed, torque, or acceleration. Often this happens when a motor manufacturer attempts to artificially position its product above the competition. Other firms design reliable motors and rate them conservatively while some advertise correct numbers under special conditions or at tolerance limits only, leaving little or no room for engineers to fine-tune the system.
For example, torque constant, Kt, typically comes with a ±10% tolerance. Although some manufacturers rate nominal Kt at the peak current, Ip, others list Kt at a smaller current, expecting it to remain within tolerance as the operating point shifts down the B-H load line with increasing current. This allows little remaining tolerance for the servo designer to manipulate at peak current conditions, and it worsens even more at elevated temperature. An industrial standard rates parametric values at 25°C ambient, but many change with temperature.
The effect of temperature on resistance is generally easy to understand, but its affect on torque loss in a motor is a bit more complex. For instance, the resistance of a motor initially starting in a room ambient temperature of 25°C, increases 50% when the winding reaches 155°C. Depending upon the magnet grade and motor's operating slope, torque sensitivity, Kt, can decrease from 3 to more than 20% over the same temperature range. Most manufacturers publish their motor ratings at 25°C because it's a traditional starting point. However, in servomotor applications where continuous duty is more typical, the magnets
are likely to see a higher temperature generated by armature heating. More conservative ratings and assurance that the user's load point will be met force manufacturers to specify the Kt at elevated temperatures. An example is a servomotor with continuous torque rated at 40°C. Only the motor manufacturer can accurately determine the derating factor because it knows the details of the motor design and materials.
Even more critical in determining whether or not a motor will achieve or even survive a continuous or stressful load condition is understanding the temperature rise per watt — the TPR parameter. However, when mounting the motor, it is conventional to specify the temperature rise with a prime mark in the symbol, TPR°. The unmounted motor is the worst-case condition, though most motors are mounted by some means. It's not unusual for the TPR to be reduced in smaller motors by a factor of 0.167 just by mounting, while air and fluid cooling reduce this value even more. The unmounted TPR is often stated on data sheets, particularly for frameless motors, because it provides a common baseline from which to estimate the derated value for specific mounting and environmental conditions. However, not all manufacturers follow this convention, so determine which temperature-rise factor is given before calculating duty cycles.
Another commonly misunderstood parameter is friction. Motor friction includes cogging, hysteresis loss, bearing friction (if housed), brush sliding contact friction (for brushtype motors) and a few other minor external influences. Most frictional components are widely understood, but the magnetically induced components of friction such as cogging and hysteresis losses often are not.
Cogging comes from changing reluctance paths while motor components rotate. When the field's magnetic poles pass the armature slot openings (air gaps) and approach the armature's metal teeth, magnetic force pulls the rotating part forward. It also grips the metal region and opposes the developed torque. A plot of this torque profile versus rotational angle looks like an erratic sine wave.
Hysteresis also plays a key role in establishing motor constants. It refers to the B-H loop of lamination material and flux density within the lamination region. It appears as a continuous component of friction even though it increases nonlinearly with frequency.
To see how this works, imagine a smooth ring with an inner multiple pole field assembly rotating at a steady speed. The magnetic flux produced by the magnets generates a frictional drag. The Hysteresis drag diagram typically illustrates the combination of these two elements' characteristics for most dc motors. Unfortunately, not all manufacturers' data sheets reflect the peak of these combined frictional components. The proper quantity to use is the starting break-away friction which includes the peak amplitude of the cogging component added to the hysteresis drag.